Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
1.
Journal of Korean Medical Science ; : e328-2021.
Article in English | WPRIM | ID: wpr-915428

ABSTRACT

Background@#In the coronavirus disease 2019 (COVID-19) pandemic era, the simultaneous detection of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), influenza virus (Flu), and respiratory syncytial virus (RSV) is important in the rapid differential diagnosis in patients with respiratory symptoms. Three multiplex real-time reverse transcription polymerase chain reaction (rRT-PCR) assays have been recently developed commercially in Korea: PowerChek™ SARS-CoV-2, Influenza A&B Multiplex Real-time PCR Kit (PowerChek; KogeneBiotech); STANDARD™ M Flu/SARS-CoV-2 Real-time Detection Kit (STANDARD M; SD BioSensor); and Allplex™ SARS-CoV-2/FluA/FluB/RSV Assay (Allplex; Seegene). We evaluated the analytical and clinical performances of these kits. @*Methods@#A limit of detection tests were performed and cross-reactivity analysis was executed using clinical respiratory samples. Ninety-seven SARS-CoV-2-positive, 201 SARS-CoV-2-negative, 71 influenza A-positive, 50 influenza B-positive, 78 RSV-positive, and 207 other respiratory virus-positive nasopharyngeal swabs were tested using the three assays. The AdvanSure™ respiratory viruses rRT-PCR assay (AdvanSure; LG Life Sciences) was used as a comparator assay for RSV. @*Results@#Except in influenza B, in SARS-CoV-2 and influenza A, there were no significant differences in detecting specific genes of the viruses among the three assays. All three kits did not cross-react with common respiratory viruses. All three kits had greater than 92% positive percent agreement and negative percent agreement and ≥ 0.95 kappa value in the detection of SARS-CoV-2 and flu A/B. Allplex detected RSV more sensitively than AdvanSure. @*Conclusion@#The overall performance of three multiplex rRT-PCR assays for the concurrent detection of SARS-CoV-2, influenza A/B, and RSV was comparable. These kits will promote prompt differential diagnosis of COVID-19, influenza, and RSV infection in the COVID-19 pandemic era.

2.
Healthcare Informatics Research ; : 47-50, 2019.
Article in English | WPRIM | ID: wpr-719266

ABSTRACT

OBJECTIVES: An automatic needle destroyer (ANDY) was developed to prevent needlestick injuries, and usability tests were conducted in several hospitals. The addition of extra features to the ANDY is in progress, such as data collection and automatic identification of used syringes. Thus, this report describes how the ANDY can be used to track the data of used syringes. METHODS: The motor torque required for barrel separation differs according to syringe diameters. By monitoring the electric current which is consumed for the motor torque, the type of syringe can be identified. Twelve prototypes were produced, and five usability tests were conducted in hospitals. RESULTS: After use, a syringe is inserted into the proposed device, and the needle portion is then cut and separated from the syringe body (barrel) and discarded. The needles are collected in a sharps container for hygienic disposal, and the barrel is dropped into a general medical waste container. CONCLUSIONS: The ANDY can be used to track the syringe used for each patient. The barcode can be read while the syringe rotates in the main body of the ANDY with a built-in omnidirectional scanner. Collection of information during syringe disposal can facilitate stock management. This system could also be extended to other types of consumable medical devices, although it would still be a challenge to differentiate each medical device.


Subject(s)
Humans , Data Collection , Disposable Equipment , Equipment and Supplies , Equipment Design , Medical Waste , Medical Waste Disposal , Needles , Needlestick Injuries , Syringes , Torque
3.
The Korean Journal of Gastroenterology ; : 370-375, 2004.
Article in Korean | WPRIM | ID: wpr-155621

ABSTRACT

BACKGROUND/AIMS: The growth of technology based on internet protocol has affected on the informatics and automatic controls of medical fields. The aim of this study was to establish the telemedical educational system by developing the high quality image transfer using the DVTS (digital video transmission system) on the high-speed internet network. METHODS: Using telemedicine, we were able to send surgical images not only to domestic areas but also to international area. Moreover, we could discuss the condition of surgical procedures in the operation room and seminar room. The Korean-Japan cable network (KJCN) was structured in the submarine between Busan and Fukuoka. On the other hand, the Korea advanced research network (KOREN) was used to connect between Busan and Seoul. To link the image between the Hanyang University Hospital in Seoul and Kyushu University Hospital in Japan, we started teleconference system and recorded image-streaming system with DVTS on the circumstance with IPv4 network. RESULTS: Two operative cases were transmitted successfully. We could keep enough bandwidth of 60 Mbps for two-line transmission. The quality of transmitted moving image had no frame loss with the rate 30 per second. The sound was also clear and the time delay was less than 0.3 sec. CONCLUSIONS: Our study has demonstrated the feasibility of domestic and international telemedicine. We have established an international medical network with high-quality video transmission over internet protocol. It is easy to perform, reliable, and also economical. Thus, it will be a promising tool in remote medicine for worldwide telemedical communication in the future.


Subject(s)
Humans , Computer Communication Networks , English Abstract , Japan , Korea , General Surgery/education , Telecommunications , Telemedicine , Video Recording
SELECTION OF CITATIONS
SEARCH DETAIL